Pressure Transmitters
Pressure Transmitters products for industrial measurement and OEM selection.
Product List
29 products
Ordered by category and product shape
Quote requiredP100 Pressure Transmitter
- Measurement range
- 0–0.1 MPa / -0.1 MPa / 100 MPa
- Output signal
- 0.5–4.5 V / 0–5 V / 0–10 V · +3 options
- Accuracy
- ±1 %FS / ±0.5 %FS / ±0.25 %FS · +2 options
Quote requiredP131 Pressure Transmitter
- Measurement range
- 0–2 MPa / 60–130 MPa
- Output signal
- 0–5 V / 0–10 V / 4–20 mA
- Accuracy
- ±0.5 %FS / ±0.25 %FS
Quote requiredP132 Pressure Transmitter
- Measurement range
- -0.1 MPa / 60 MPa
- Output signal
- 0–5 V / 0–10 V / 4–20 mA
- Accuracy
- ±0.5 %FS / ±0.25 %FS
Quote requiredP140 Pressure Transmitter
- Measurement range
- 400 bar
- Overload limit
- x rated pressure
Quote requiredP150 Pressure Transmitter
- Output signal
- 4–20 mA / 0–10 V / 0–5 V
P150 Pressure Transmitters for industrial measurement and control applications. Datasheet is archived for model selection, specification review, purchasing communication, and maintenance records.
View Details
Quote requiredP160 Pressure Transmitter
- Measurement range
- 0–40 kPa / 2.5 MPa
- Output signal
- 0.5–4.5 V / 0–5 V / 0–10 V · +3 options
- Accuracy
- ±1 %FS / ±0.5 %FS / ±0.25 %FS
Quote requiredP110 Pressure Transmitter
- Overload limit
- x rated pressure≤ x rated pressure≤
P110 Pressure Transmitters for industrial measurement and control applications. Datasheet is archived for model selection, specification review, purchasing communication, and maintenance records.
View Details
Quote requiredP1101 Pressure Trasmitters
- Measurement range
- 0–5 bar / 10 bar / 16 bar · +2 options
- Output signal
- 0.5–4.5 V / 0–5 V / 0–10 V · +2 options
- Accuracy
- ±1 %FS / ±0.5 %FS
Quote requiredP13 Pressure Transmitter
- Measurement range
- 0–20 bar
- Output signal
- 0.5–4.5 V
- Accuracy
- ±1.5% / ±3%
Quote requiredP20 Pressure Transmitter
- Measurement range
- −1 to +10 bar / 16 bar / 25 bar · +3 options
- Output signal
- 0.5–4.5 V
- Accuracy
- ±1 %FS
Quote requiredP111 Pressure Transmitter
- Measurement range
- 0–10 kPa / -100 kPa / 100 kPa · +2 options
- Output signal
- 0.5–4.5 V / 0–5 V / 1–5 V · +3 options
- Accuracy
- ±1 %FS / ±0.5 %FS / ±0.25 %FS
Quote requiredP1102 Pressure Transmitter
- Measurement range
- −1 to +10 bar / 16 bar / 25 bar · +3 options
- Output signal
- 0.5–4.5 V / 0–5 V / 0–10 V · +2 options
- Accuracy
- ±1 %FS / ±0.5 %FS
Quote requiredP180 Pressure Transmitter
- Measurement range
- 600 bar
- Output signal
- 0.5–4.5 V / 0–5 V / 0–10 V · +2 options
- Accuracy
- ±1 %FS / ±0.5 %FS / ±0.25 %FS
Quote requiredP1104 Pressure Transmitter
- Measurement range
- 0–10 bar / 16 bar / 25 bar · +1 options
- Output signal
- 0.5–4.5 V / 4–20 mA
- Accuracy
- ±1 %FS / ±0.5 %FS
Quote requiredP1104E Pressure Transmitter
- Measurement range
- 0–2 bar / 4 bar / 6 bar · +4 options
- Output signal
- 0.5–4.5 V / 0–5 V / 1–5 V · +3 options
- Accuracy
- ±1 %FS / ±0.5 %FS / ±0.25 %FS
Quote requiredP170 Pressure Transmitter
- Measurement range
- 400–600 bar
- Output signal
- 0.5–4.5 V / 0–5 V / 0–10 V · +2 options
- Accuracy
- ±1 %FS / ±0.5 %FS / ±0.25 %FS
Quote requiredP1103 Pressure Transmitter
- Measurement range
- 0–1 MPa
- Output signal
- 0.1–3.2 V
- Accuracy
- ±1.5 %FS / ±2.5 %FS
Quote requiredP1105 Pressure Transmitter
- Measurement range
- 0–4 bar / 6 bar / 10 bar · +1 options
- Output signal
- 0.5–4.5 V / 0.5–2.5 V / 0.5–3.5 V
- Accuracy
- ±1.5 %FS / ±2.5 %FS
Quote requiredP10 Pressure Transmitter
- Measurement range
- 0–0.5 MPa / 1 MPa / 1.6 MPa · +3 options
- Output signal
- 0.5–4.5 V / 0–5 V / 0–10 V · +2 options
- Accuracy
- ±1 %FS / ±0.5 %FS / ±0.25 %FS
Quote requiredP10C Pressure Transmitter
- Measurement range
- 0–6 bar / 10 bar / 16 bar · +1 options
- Output signal
- 0.5–4.5 V / 0–5 V / 0–10 V · +1 options
- Accuracy
- ±1% / 0.5 %FS
Quote requiredP11 Pressure Transmitter
- Measurement range
- 0–1 MPa / 1.6 MPa / 2 MPa · +2 options
- Output signal
- IIC
- Accuracy
- ±1.5% / ±3%
Quote requiredP12 Pressure Transmitter
- Measurement range
- 0–10 bar / 16–20 bar / 25 bar
- Output signal
- 0.5–4.5 V
- Accuracy
- ±1.5% / ±3%
Quote requiredP21C Pressure Transmitter
- Measurement range
- −1 to +10 bar / 16 bar / 25 bar · +3 options
- Output signal
- 0.5–4.5 V / 0–5 V / 0–10 V · +2 options
- Accuracy
- ±1% / 0.5 %FS
Quote requiredPXF Pressure Transmitter
- Measurement range
- 0–6 bar / -10 bar / -16 bar · +3 options
- Accuracy
- ±1 %FS / ±0.5 %FS / ±0.25 %FS
- Overload limit
- 3 x rated pressure
MODEL COMPARISON
Pressure Transmitters — Quick Specification Comparison
| Model | Measurement range | Output signal | Accuracy | Details |
|---|---|---|---|---|
| P100 | 0–0.1 MPa / -0.1 MPa / 100 MPa | 0.5–4.5 V / 0–5 V / 0–10 V · +3 options | ±1 %FS / ±0.5 %FS / ±0.25 %FS · +2 options | Specs |
| P131 | 0–2 MPa / 60–130 MPa | 0–5 V / 0–10 V / 4–20 mA | ±0.5 %FS / ±0.25 %FS | Specs |
| P132 | -0.1 MPa / 60 MPa | 0–5 V / 0–10 V / 4–20 mA | ±0.5 %FS / ±0.25 %FS | Specs |
| P140 | 400 bar | — | — | Specs |
| P150 | — | 4–20 mA / 0–10 V / 0–5 V | — | Specs |
| P160 | 0–40 kPa / 2.5 MPa | 0.5–4.5 V / 0–5 V / 0–10 V · +3 options | ±1 %FS / ±0.5 %FS / ±0.25 %FS | Specs |
| P110 | — | — | — | Specs |
| P1101 | 0–5 bar / 10 bar / 16 bar · +2 options | 0.5–4.5 V / 0–5 V / 0–10 V · +2 options | ±1 %FS / ±0.5 %FS | Specs |
| P13 | 0–20 bar | 0.5–4.5 V | ±1.5% / ±3% | Specs |
| P20 | −1 to +10 bar / 16 bar / 25 bar · +3 options | 0.5–4.5 V | ±1 %FS | Specs |
SELECTION GUIDE
How to Select an Industrial Pressure Transmitter
Match measuring range, wetted materials, electrical output, and process thread to your real operating media and PLC architecture before requesting samples or OEM customization.
1. Size Range with Overpressure Margin
Choose a full-scale range 1.5x–2x above normal working pressure so routine operation sits between 30% and 75% span while surviving pump start/stop spikes and water hammer.
2. Choose the Right Output Signal
Use 2-wire 4–20 mA for long-distance PLC/DCS runs and high EMI immunity, 0–5 V / 0–10 V / 0.5–4.5 V for compact OEM boards, or RS-485 Modbus RTU for multi-point digital telemetry.
3. Verify Wetted Material & Media
Standard 316L stainless steel diaphragms cover water, hydraulic oil, and air; ceramic cells resist mildly corrosive fluids and abrasive particles.
4. Confirm Thread & Ingress Protection
Specify G1/4, NPT1/4, G1/2, or M20×1.5 process threads and M12 / Packard / Hirschmann connectors with IP65–IP68 sealing for outdoor or washdown equipment.
Pressure Transmitters FAQ
What is the difference between a pressure sensor and a pressure transmitter?
A pressure sensor typically outputs a raw millivolt or ratiometric voltage signal for embedded OEM electronics, whereas a pressure transmitter integrates signal conditioning and temperature compensation to deliver standardized industrial outputs such as 4–20 mA, 0–10 V, or RS-485.
Can YUFAVOR customize pressure ranges, threads, and connectors for OEM orders?
Yes. Standard OEM customization covers non-standard pressure ranges, G/NPT/M20/SAE process connections, M12/Packard/cable electrical interfaces, private labeling, and multi-point calibration reports.
What accuracy grades are available for industrial pressure transmitters?
Depending on the model series and sensing element, YUFAVOR offers ±0.25% FS, ±0.5% FS, and ±1.0% FS accuracy options across diffused silicon and ceramic core platforms.