Differential Pressure Transmitters
Differential Pressure Transmitters products for industrial measurement and OEM selection.
Product List
3 products
Ordered by category and product shape
Quote requiredP120 Differential Pressure Transmitter
- Measurement range
- 0–10 kPa / 100–600 kPa / 1 MPa · +1 options
- Output signal
- 0.5–4.5 V / 0–5 V / 0–10 V · +3 options
- Accuracy
- ±1 %FS / ±0.5 %FS / ±0.25 %FS
Quote requiredP400 Differential Pressure Transmitter
- Measurement range
- −1000 to +1000 Pa / −500 to +500 Pa / −250 to +250 Pa
- Output signal
- 0–10 VDC / 4–20 mA / RS-485
- Accuracy
- ±1 %FS
Quote requiredP410 Differential Pressure Transmitter
- Measurement range
- −1000 to +1000 Pa / −500 to +500 Pa / −250 to +250 Pa
- Output signal
- 0–10 VDC / 4–20 mA / RS-485
- Accuracy
- ±1 %FS
MODEL COMPARISON
Differential Pressure Transmitters — Quick Specification Comparison
| Model | Measurement range | Output signal | Accuracy | Details |
|---|---|---|---|---|
| P120 | 0–10 kPa / 100–600 kPa / 1 MPa · +1 options | 0.5–4.5 V / 0–5 V / 0–10 V · +3 options | ±1 %FS / ±0.5 %FS / ±0.25 %FS | Specs |
| P400 | −1000 to +1000 Pa / −500 to +500 Pa / −250 to +250 Pa | 0–10 VDC / 4–20 mA / RS-485 | ±1 %FS | Specs |
| P410 | −1000 to +1000 Pa / −500 to +500 Pa / −250 to +250 Pa | 0–10 VDC / 4–20 mA / RS-485 | ±1 %FS | Specs |
SELECTION GUIDE
Selecting Differential Pressure Transmitters for Filters, HVAC & Process Lines
Differential pressure measurement requires checking both the differential span and the maximum static line pressure on both ports.
1. Separate Differential Span from Static Pressure
Low-pressure HVAC/cleanroom ducts operate in Pa or kPa ranges (e.g., ±250 Pa to ±1000 Pa), while liquid filter and pipeline applications may experience high static line pressure on both ports.
2. Check Media Compatibility on Both Ports
Confirm whether dry air/non-corrosive gas (micro-DP models like P400/P410) or liquid/wet process media (stainless wet-wet models like P120) contacts the high and low ports.
3. Select Unidirectional or Bidirectional Span
Use unidirectional ranges (0–10 kPa) for filter clogging alarms and bidirectional ranges (−500 to +500 Pa) for positive/negative cleanroom pressure monitoring.
4. Integrate with BMS or PLC Controls
Choose 4–20 mA, 0–10 VDC, or RS-485 Modbus outputs for direct connection to HVAC building management systems or industrial PLCs.
Differential Pressure Transmitters FAQ
How do differential pressure transmitters detect filter clogging?
By connecting the high-pressure port upstream and the low-pressure port downstream of a filter, the transmitter tracks pressure drop across the element and triggers a maintenance alarm once the differential exceeds your threshold.
Can air differential pressure transmitters measure liquids?
No. Air/gas micro-differential transmitters are designed for dry, non-corrosive gases only. Liquid or wet-media differential measurement requires wet-wet isolated diaphragms such as the P120 series.
What outputs are available for HVAC and industrial DP transmitters?
Standard models provide 4–20 mA, 0–10 VDC, 0–5 V, 0.5–4.5 V, and RS-485 digital outputs with IP65 to IP68 enclosure options.